Welcome to Tianjin Yibiao Valve Manufacturing Co., Ltd!
中文版 WeChat:
 
Product

Electric single seat regulating valve

Brand:Pneumatic eccentric butterfly valve    型号:KHLS

Electric single seat regulating valve
Product Definition and Working Principle
Electric single seat regulating valve is a pressure balanced regulating valve composed of an electric actuator and a straight through single seat valve body. It drives the valve core to move by receiving 4-20mA or 0-10V DC signals, changing the flow area to accurately control parameters such as medium pressure and flow rate.
Its core features include:
S streamline channel: reduces fluid resistance and improves flow stability.
Dual directional structure: good dynamic stability, low leakage (soft seal VI level ≤ 0.01% valve capacity).
Key performance parameters
Parameter specifications
Nominal diameter DN20-DN300
Pressure rating PN1.6-PN64 (American standard 150LB-1500LB)
Applicable temperature -196 ℃~450 ℃
Flow characteristics: straight line/equal percentage/fast opening
Sealing grade ANSI B16.104 Grade VI




The KHLS electric single seat regulating valve has a compact structure with an S-shaped channel, which reduces pressure drop loss, increases flow rate, has a wide adjustable range, and high flow characteristic accuracy, complying with the IEC534 standard. The leakage rate of the regulating valve complies with ANSI B16.104 standard. The regulating valve is equipped with a multi spring thin film actuator and electric actuators such as PSL, 361l, 3810, etc. Its structure is compact, the output force is large, and the product complies with GB/T4213-92.
performance
Leakage rate: Metal valve seat: less than 0.01% of the rated capacity of the valve, in compliance with ANSI B16.104-1976 Class IV
Soft seat: 10-7 less than the rated capacity of the valve, in compliance with ANSI B16.104-1976 Class IV
Return difference: Pneumatic with locator: less than 1% of full stroke, without locator: less than 3% of full stroke (LHA1 type less than 5% of full stroke)
The electric DKZ actuator is 1.5%; 2% for 361L actuator; 1% for RS execution mechanism; Equipped with PSL actuator at 1%
Basic error: Pneumatic with locator: less than ± 1% of full stroke, without locator: less than ± 5% of full stroke
The electric actuator with DKZ actuator has a tolerance of ± 2.5%; Equipped with 361L actuator for ± 2%; Equipped with an RS actuator of ± 1%; Equipped with PSL actuator for ± 1%
Note: Standard V-shaped polytetrafluoroethylene packing is used

Bace
WeChat
QQ
点击咨询

Tianjin Yibiao Valve Manufacturing Co., Ltd


Ph:138-2033-8668

Add:No.3 Road, Jiuyuan Industrial Zone, Baodi, Tianjin
Tel:022-26798533
Post:300240

版权所有 Copyright ◎ 2025 Tianjin Yibiao Valve Manufacturing Co., Ltd Rights Reserved. ICP:08100650号-9