Welcome to Tianjin Yibiao Valve Manufacturing Co., Ltd!
中文版 WeChat:
 
Product

Differential pressure bypass balance valve

Brand:Pneumatic eccentric butterfly valve    

Differential pressure bypass balancing valve is a hydraulic control valve that achieves system balance through the pressure difference of the medium itself. It is widely used in parallel fire and domestic water supply systems as well as air conditioning systems. The following are its main features and applications:
1. Function and working principle
Dynamic adjustment: By sensing the change in inlet and outlet pressure difference through a pilot valve, the main valve opening is adjusted using a negative feedback mechanism to stabilize the pressure difference at the set value.
Switching between fire protection and domestic water supply: In case of a fire, the domestic water supply is cut off to ensure the fire protection water supply, and the domestic water supply is automatically restored after the fire pressure is reduced.
Application of air conditioning system: Balance the pressure difference between supply and return water, reduce system noise and equipment loss.
2. Structure and composition
Main components: including main valve, differential pressure control pilot valve, needle valve, ball valve, and micro filter.
Material and Connection: The valve body material is mostly ductile iron or stainless steel, and flange or groove connections are used.
3. Technical parameters
Pressure rating: The nominal pressure range is 0.6-4.0 MPa, and the shell test pressure is 1.5 times the nominal pressure.
Applicable medium: water, working temperature 0-80 ℃ (some models can reach up to 150 ℃).
4. Installation and maintenance
Installation requirements: A filter should be installed before the valve, and the direction of the arrow on the main valve body should be consistent with the flow direction of the pipeline.
Maintenance points: Regularly inspect vulnerable parts such as diaphragms to ensure valve sensitivity.
5. Advantages
Energy saving intelligence: No need for external energy drive, completely relying on medium pressure difference to achieve balance.
Cost savings: Reduce the construction cost of individual fire protection pipelines and improve system utilization.
6. Classification and Expansion
Electric differential pressure bypass valve: Used in central air conditioning systems, it adjusts the opening through an electric actuator to maintain a constant pressure differential.
800X series: designed specifically for fire and domestic water supply, compatible with DN20-DN800 pipe diameters.



选型建议


Bace
WeChat
QQ
点击咨询

Tianjin Yibiao Valve Manufacturing Co., Ltd


Ph:138-2033-8668

Add:No.3 Road, Jiuyuan Industrial Zone, Baodi, Tianjin
Tel:022-26798533
Post:300240

版权所有 Copyright ◎ 2025 Tianjin Yibiao Valve Manufacturing Co., Ltd Rights Reserved. ICP:08100650号-9